Short #46 - Surge Protection
HVAC School - For Techs, By Techs
Bryan Orr
4.9 • 1K Ratings
🗓️ 19 March 2019
⏱️ 14 minutes
🧾️ Download transcript
Summary
Today's short podcast episode is all about surge protection on HVAC/R equipment. Lightning poses a severe threat to equipment, and surge suppression may or may not help.
Unfortunately, surge protection cannot protect HVAC equipment from direct lightning strikes. Surge suppression strategies connect to the high-voltage line and will protect your equipment from surges from the utility. Large, instantaneous spikes in voltage can mess up your equipment quite severely.
In general, we install MOVs (metal oxide varistors) as surge protectors in residential and light commercial equipment. Series mode (SM) acts as a low-pass filter that blocks higher frequencies, but MOVs are our main go-to for surge protection. When the voltage is within the clamping voltage, the metal oxide varistor shunts or redirects current to ground instead of the device; these devices have very high resistance, and they can fail when they get too hot. In thermal runaway, the MOV is very hot but continues shunting the current; as a result, the MOV is at risk of catching on fire. Thermal protection can exist for MOVs. MOVs also need a strong, secure ground connection to operate correctly. Make sure the MOV is connected, and a good way to do that is to test from leg to ground.
MOVs also require careful consideration during installation. These surge protectors can fit inside an ICM493 box that prevents catastrophic fire in the case of thermal runaway. Overvoltages below the clamping voltage can occur on MOVs, especially on inverter-driven compressors. ICM493s can also control overvoltages because they have voltage-monitoring capabilities (however, there is no published Joule rating). Both the LBK10 and ICM493 can shut off the equipment in the case of MOV failure.
Learn more about Refrigeration Technologies HERE.
If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.
Transcript
Click on a timestamp to play from that location
| 0:00.0 | Hey, this is a short episode of the HVAC School Podcast. I'm Brian. This is the |
| 0:07.2 | podcast that helps you remember some things that you might have forgotten along |
| 0:09.7 | the way and it also helps you remember some things you forgot to know in the first place. |
| 0:13.3 | This is a high demand episode. |
| 0:16.0 | We're talking about surge protection, surge suppression, whatever you want to call it. |
| 0:21.6 | But that's what we're talking about today. |
| 0:22.8 | But before we do that, I want to thank our sponsors, |
| 0:25.1 | carrier and carrier.com. |
| 0:27.0 | I also want to thank fieldpiece, |
| 0:29.2 | field piece makers of the MR.45 and VP85. |
| 0:32.4 | MR. 45 is the recovery machine. |
| 0:34.8 | V.P.85 is the vacuum pump, |
| 0:36.6 | as well as the job link probes that work with Measure Quick. |
| 0:39.3 | If you haven't taken a look at all these, you can go to truetech tools. |
| 0:42.3 | Come to have a look. Use the offer code get school. look at |
| 0:45.0 | true tech tools.com to have a look use the offer code get schooled for a discount |
| 0:46.0 | refrigeration technologies at refriggedec.com |
| 0:49.0 | navac and navac global.com |
| 0:52.0 | and then finally Speed Clean. |
| 0:53.6 | Speed Clean is a new sponsor of the podcast and we recently did a giveaway on the |
| 0:58.9 | coil shot. |
| 1:00.0 | Coil shot is a really interesting solution to cleaners, so check that out. |
... |
Please login to see the full transcript.
Disclaimer: The podcast and artwork embedded on this page are from Bryan Orr, and are the property of its owner and not affiliated with or endorsed by Tapesearch.
Generated transcripts are the property of Bryan Orr and are distributed freely under the Fair Use doctrine. Transcripts generated by Tapesearch are not guaranteed to be accurate.
Copyright © Tapesearch 2026.